CADEANCO

bar1.jpg (2136 bytes)

OEM Data Logging Systems

[Click on a thumbnail to view full image]

 

CADEANCO manufactures a family of OEM data loggers for clients that are custom designed to record data from their range of sensors for geotechnical applications.   The loggers are housed in a polycarbonate case designed for clients to incorporate in their own external case.   Connections to the logger are easily made via screw terminal connectors and a series of pre-drilled cable access ports provides flexibility for cabling.  The loggers use an external, user-supplied power source including the option of a lead-acid battery with solar charging or AC power module.  With a stand-by current of only 65uA, these loggers are ideal for use in applications where re-charging is impractical and access for battery replacement is difficult.

 

 

Specifications

 

Download
Operating Manual

 

 

OEM VIBRATING WIRE DATA LOGGER

Description

The Vibrating Wire Data Logger can measure up to twenty-four  independent devices using vibrating wire technology.  The flexibility of this logger makes it ideal for stand-alone monitoring in geotechnical, mining and rural applications such as:-

  • VW Piezometers
  • VW Strain Gauges
  • VW Stress Cells
  • VW Pressure Cells
  • VW Temperature Gauges

Features

  • User Flexibility for Installation 
  • Stand-alone Operation
  • Multiple Power Options
  • High-speed RS232 Communication
  • Up to 24 Input Channels
  • Inbuilt lightning protection on all inputs
  • Up to5450 Scan Memory Capacity
  • Menu-driven User Options
  • Simplified Sensor Connection
  • GSM or PSTN Modem Access Option

Specifications

 

Download
Operating Manual

OEM EXTENSOMETER DATA LOGGER

Description

Designed specifically for three or six channel extensometer heads and single channel crackmeters, the Extensometer Data Logger can record data from up to twenty-four independent single-end voltage input channels.   The logger can also be configured for direct voltage input making it ideal for stand-alone monitoring in both laboratory and field applications such as:-

  • Displacement Sensors
  • Water Level Indicators
  • Flow Monitoring
  • Wind Speed Sensors
  • Slope Stability Monitoring
  • Temperature Gauges
  • Rainfall Monitoring

Features

  • User Flexibility for Installation
  • Stand-alone Operation
  • Multiple Power Options
  • 4V Sensor Power Outputs
  • High-speed RS232 Communication
  • Up to 24 Single-end Input Channels
  • Inbuilt lightning protection on all inputs
  • Optional Lead-wire Compensation
  • Over 5450 Scan Memory Capacity
  • Menu-driven User Options
  • Simplified Sensor Connection